II Parameters
Base Specifications Parameters
II - 25
#1223 aux07
bit3: Synchronous tapping in-position check valid
0: Disable (Conventional method: execute same in-position check at the hole bottom/R
point)
1: Enable (Extension method: able to select the in-position check enable/disable at the
hole bottom/R point)
Related parameters:
#1223/bit4 Synchronous tapping hole bottom in-position check
bit4: Synchronous tapping hole bottom in-position check
Select enable/disable of Synchronous tapping hole bottom in-position check.
0: Disable
1: Enable
bit6: Synchronous tapping (,S) cancel
0: Retain a spindle speed (, S) when performing synchronous tapping retract.
1: Cancel a spindle speed (, S) by retract with G80.
bit7: Synchronous tapping method
Select a synchronous tapping method.
0: Enable multi-step acceleration/deceleration and rapid return synchronous tapping
1: Disable multi-step acceleration/deceleration and rapid return synchronous tapping
#1224 aux08
bit0: Data sampling valid
Set valid/invalid for the data sampling.
0: Setting of sampling parameter invalid
1: Setting of sampling parameter valid
#1225 aux09
bit5: Alarm history recording option of the safety observation warning
Select whether to record "Y21 Safety observation warning 0001" (Speed obsv signal:
Speed over) to the alarm history.
0: Record
1: Not record