II Parameters
Axis Specifications Parameters
II - 56
#2165 exdcax6 External deceleration speed 6
Set the upper limit of the feedrate when the external deceleration signal is ON and only one
axis is moved. In automatic operation, the upper limit of the combined speed is applied.
Set #2086 when using the external deceleration for each axis, and #2161 - #2165 when
using the external deceleration 2nd step or later.
This parameter is enabled when "#1239 set11/bit6" is set to "1".
---Setting range---
1 to 1000000(mm/min)
#2179 TapInpI In-position width for Tapping initial point
Set the in-position check width for synchronous tapping I point.
The value of "#2224 sv024" is applied when it is set "0".
* This parameter is enabled only when "#1223/bit3" and "#1245/bit0 or bit1" are "1".
---Setting range---
0 to 99.999 (mm)
#2180(PR) S_DIN Speed monitor input door No.
Set the door signal input in the drive unit.
Use this parameter only when the axis with a door signal belongs to several door groups.
The correspondence between the door signals and bits are as follows.
bit0 : Door1 signal
bit1 : Door2 signal
:
bitF : Door16 signal
If the axis does not receive any door signal, set to "0".
An error (Y20 0027) will occur in the following cases.
- Several bits are enabled.
- Any bit other than those set in "#2118 S_DSl" is enabled.
---Setting range---
0000 to FFFF (HEX)
#2181(PR) sscfeed1 Safety observation speed 1
Set the safety observation speed, which is at the machine end, in the multi-step speed
monitor mode 1.
---Setting range---
0 to 18000 (mm/min or °/min)
#2182(PR) sscfeed2 Safety observation speed 2
Set the safety observation speed, which is at the machine end, in the multi-step speed
monitor mode 2.
---Setting range---
0 to 18000 (mm/min or °/min)
#2183(PR) sscfeed3 Safety observation speed 3
Set the safety observation speed, which is at the machine end, in the multi-step speed
monitor mode 3.
---Setting range---
0 to 18000 (mm/min or °/min)
#2184(PR) sscfeed4 Safety observation speed 4
Set the safety observation speed, which is at the machine end, in the multi-step speed
monitor mode 4.
---Setting range---
0 to 18000 (mm/min or °/min)
#2187(PR) chgPLCax PLC axis switchover axis No.
Set the I/F No. of a PLC axis to use when switching between NC axis and PLC axis. Set the
I/F No. of a vacant PLC axis. Set to "0" when not using.
---Setting range---
0 to 8
#2605(PR) BR_SIG Brake output signal number
Set a safety signal number for executing the brake test.
The brake test is not executed when "0" is set.
(E.g.) If "0x0c" is set, the brake output signal is Y0C on the side of PLC or Y20C on the side
of NC (when initial device number is 200).
* The safety output signal set in this parameter does not check the signal state on the NC
side and PLC side during brake test.
---Setting range---
0 to 0x1FF
#2606(PR) BR_WT Brake test command waiting time
Set the lead time between NC receiving the brake test start signal and NC sending out the
movement command for the brake test.
This set time is also the time from test pattern end until the next test pattern.
The waiting time is 400(ms) when "0" is set.