II Parameters
PLC Axis Indexing Parameters
II - 168
【#12886】 PSW08-2 PSW8 area setting 2
Set "PSW8 area setting" 1 and 2 to specify the area where the position switch 8 will turn ON
when the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the
position switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
【#12887】 PSW09-1 PSW9 area setting 1
Set "PSW9 area setting" 1 and 2 to specify the area where the position switch 9 will turn ON
when the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the
position switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
【#12888】 PSW09-2 PSW9 area setting 2
Set "PSW9 area setting" 1 and 2 to specify the area where the position switch 9 will turn ON
when the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the
position switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
【#12889】 PSW10-1 PSW10 area setting 1
Set "PSW10 area setting" 1 and 2 to specify the area where the position switch 10 will turn
ON when the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the
position switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
【#12890】 PSW10-2 PSW10 area setting 2
Set "PSW10 area setting" 1 and 2 to specify the area where the position switch 10 will turn
ON when the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the
position switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
【#12891】 PSW11-1 PSW11 area setting 1
Set "PSW11 area setting" 1 and 2 to specify the area where the position switch 11 will turn
ON when the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the
position switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
【#12892】 PSW11-2 PSW11 area setting 2
Set "PSW11 area setting" 1 and 2 to specify the area where the position switch 11 will turn
ON when the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the
position switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
【#12893】 PSW12-1 PSW12 area setting 1
Set "PSW12 area setting" 1 and 2 to specify the area where the position switch 12 will turn
ON when the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the
position switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)
【#12894】 PSW12-2 PSW12 area setting 2
Set "PSW12 area setting" 1 and 2 to specify the area where the position switch 12 will turn
ON when the machine is positioned.
Whether the value of setting 1 is larger than setting 2 (or vice versa) does not affect the
position switch operation.
For rotary axes, the output turns ON in the area excluding 0.000 degree.
---Setting range---
-99999.999 to 99999.999(° or mm)